connUnitPortStatus

OID
Description
Note

connUnitPortTransmitterType

OID
Description
Note

connUnitPortModuleType

OID
Description
230 FibreAlliance MIB objects
1.3.6.1.3.94.1.10.1.7
An overall protocol status for the port:
• unknown (1)
• unused (2): Device cannot report this status.
• ready (3):FCAL Loop or FCPH Link reset protocol initialization has
completed.
• warning (4): Do not use.
• failure (5): Do not use.
• notparticipating (6): Loop is not participating and does not have a loop address.
• initializing (7): Protocol is proceeding.
• bypass (8): Do not use.
• ols (9): FCP offline status. (Not supported in Fabric OS 2.6.1.)
For an E, F, or FL_Port, the value is 3 (ok). For a U_Port, the value is 2 (unused) if not faulty
with GBIC, 3 (warning) if not faulty but no GBIC, or 5 (failure) if faulty.
1.3.6.1.3.94.1.10.1.8
The technology of the port transceiver:
• unknown (1)
• other (2)
• unused (3)
• shortwave (4)
• longwave (5)
• copper (6)
• scsi (7)
• longwaveNoOFC (8)
• shortwaveNoOFC (9)
• longwaveLED (10)
• ssa (11) (Not supported in Fabric OS 2.6.1.)
For an external FC_Port, this value should be 9 (shortwaveNoOFC), 8
(longwaveNoOFC), or 6 (copper).
1.3.6.1.3.94.1.10.1.9
The module type of the port connector:
• unknown (1)
• other (2)
• gbic (3)
• embedded (4): Fixed (oneXnine)
• glm (5)
• gbicSerialId (6)
• gbicNoSerialId (7)
• gbicNotInstalled (8)
• smallFormFactor (9)