Swfcportindex; Swfcporttype; Swfcportphystate; Swfcportopstatus - HP StorageWorks 2/64 - Core Switch Reference Manual

Hp storageworks fabric os 5.x mib reference guide (aa-rvhxb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

swFCPortIndex

OID
Description
Note

swFCPortType

OID
Description
Note

swFCPortPhyState

OID
Description

swFCPortOpStatus

OID
Description
160 SW MIB objects
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1
The switch port index.
The physical port number of the switch, plus 1. The valid values for the Core Switch 2/64,
SAN Director 2/128, and 4/256 SAN Director are 0 through maximum number of ports.
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.2
The type of ASIC for the switch port. Possible values are:
• stitch (1)
• flannel (2)
• loom (3): HP StorageWorks 1 GB switches
• bloom (4): SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core Switch
2/64, and SAN Director 2/128
• rdbloom (5)
• wormhole (6)
• unknown (7): 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 4/32, 4/256 SAN
Director, and Brocade 4Gb SAN Switch for HP p-Class BladeSystem
The valid value for the SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, Core
Switch 2/64, and SAN Director 2/128 is 4.
The valid value for 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 4/32, 4/256
SAN Director, and Brocade 4Gb SAN Switch for HP p-Class BladeSystem is 7.
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3
The physical state of the port. Possible values are:
• noCard (1): No card is present in this switch slot.
• noTransceiver (2): No Transceiver module is present in this port (Transceiver is the
generic name for gigabit interface converter (GBIC), SFP, and so forth).
• laserFault (3): The module is signaling a laser fault (defective GBIC).
• noLight (4): The module is not receiving light.
• noSync (5): The module is receiving light but is out of sync.
• inSync (6): The module is receiving light and is in sync.
• portFault (7): The port is marked faulty (defective GBIC, cable, or device).
• diagFault (8): The port failed diagnostics (defective G_Port or FL_Port card
or motherboard).
• lockRef (9): The port is locking to the reference signal.
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4
The operational status of the port. Possible values are:
• Unknown (0): The port module is physically absent.
• Online (1): User frames can be passed.
• Offline (2): No user frames can be passed.
• Testing (3): No user frames can be passed.
• Faulty (4): The port module is physically faulty.