HP StorageWorks P9000 Reference Manual page 88

Raid manager reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Example 1: raidvchkscan command example with the -v cflag option
# raidvchkscan -p CL1-A -v cflag
PORT# /ALPA/C TID# LU#
CL1-A / ef/ 0
CL1-A / ef/ 0
Output of the raidvchkscan command with -v cflag option:
BR-W-E-E: Displays the flags for checking regarding data block size.
R =E: Checking for data block size on Read is enabled.
D: Checking for data block size on Read is disabled.
W =E: Checking for data block size on Write is enabled.
D: Checking for data block size on Write is disabled.
E =L: Data block on Read/Write is interpreted as little endian format.
B: Data block on Read/Write is interpreted as big endian format.
E =W: Shows the Warning that Read/Write is not rejected when validation error is detected.
R: Shows the Reject that Read/Write is rejected when validation error is detected.
MR-W-B: Displays the flags for checking regarding CHK-F3 in the data block.
R =E: Checking for CHK-F3 on Read is enabled.
D: Checking for CHK-F3 on Read is disabled.
W =E: Checking for CHK-F3 on Write is enabled.
D: Checking for CHK-F3 on Write is disabled.
B =E: Checking for CHK-F3 in the data block #0 is enabled.
D: Checking for CHK-F3 in the data block #0 is disabled.
BR-W-B-Z: This column displays the flags for checking regarding CHK-F2 in the data block.
R =E: Checking for CHK-F2 on Read is enabled.
D: Checking for CHK-F2 on Read is disabled.
W =E: Checking for CHK-F2 on Write is enabled.
D: Checking for CHK-F2 on Write is disabled.
B =E: Comparing for CHK-F2 in the data block is enabled. D: Comparing for CHK-F2 in the data
block is disabled.
Z =E: The NON zero checking for CHK-F2 in the data block is enabled.
D: The NON zero checking for CHK-F2 in the data block is disabled.
SR-W-B-S: Displays the flags for checking regarding CHK-F1 in the data block.
R =E: Checking for CHK-F1 on Read is enabled.
D: Checking for CHK-F1 on Read is disabled.
W =E: Checking for CHK-F1 on Write is enabled.
D: Checking for CHK-F1 on Write is disabled.
B =E: Checking for CHK-F1 in the data block #0 is enabled.
D: Checking for CHK-F1 in the data block #0 is disabled.
S =E: Referring for CHK-F1 flag contained in the data block is enabled.
D: Referring for CHK-F1 flag contained in the data block is disabled.
Example 2: raidvchkscan command example with the -v offset option
# raidvchkscan -p CL1-A -v offset
PORT# /ALPA/C TID# LU#
CL1-A / ef/ 0
88
Replication commands
Seq#
Num LDEV#
0
0
2332
1
0
1
2332
1
Seq#
Num LDEV#
0
0
2332
1
BR-W-E-E
MR-W-B
0
D E B R
D D D
1
D E B R
D D D
Bsize
STLBA
0
1024
BR-W-B-Z
SR-W-B-S
D E E E
D E D D
D E E E
D E D D
ENLBA BNM
1
102400
9