HP StorageWorks P9000 Reference Manual page 181

Raid manager reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

-T
This displays the type of physical path.
F:FIBRE, E:ESCON,
-STS
This displays the following status of the CU.
- NML: this means the status of "Normal" in CU.
- WAR: this means the status of "Warning" in CU.
- ERR: this means the status of "Failing" in CU.
- UNK: this means the status of "Unknown" in CU.
-MP
This displays the number of path as minimum.
-NP
This displays the number of path setting between MCU and RCU.
-IM
This displays the incident mode setting to RCU.
MR: it sends incident to MCU host and RCU host
RO: it sends incident only to RCU host
If CU free is specified for RCU, "-" is displayed.
-FZ
This displays the freeze option.
D: the freeze option is disable
E: the freeze option is enable
If CU free is specified for RCU, "-" is displayed.
-RTO (s)
This displays the timeout value for RIO (Remote IO) setting between MCU and RCU.
-RTT (ms)
This displays the round trip time value between MCU and RCU.
# raidcom get rcu -cu_free 64034 4 1
Serial# ID PID MCU RCU M/R T PNO MPORT RPORT STS_CD SSIDs
64034 R7 1 - - RCU F 1 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 2 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 3 CL1-A CL1-B NML_01 -
Description on each column in output example
-Serial#
Product serial number.
-ID
This displays the ID for identifying RAID type.
XP12000 Disk Array/XP10000 Disk Array :R5, XP24000/XP20000 Disk Array : R6, P9500 : R7
PID
This displays a path group ID.
If CU is specified for RCU, "-" is displayed.
-MCU
raidcom get rcu