Using Manual Configuration - Lenovo ThinkServer RD240 Software User's Manual

Megaraid sas software user guide
Hide thumbs Also See for ThinkServer RD240:
Table of Contents

Advertisement

4.4.3

Using Manual Configuration

4.4.3.1
Using Manual Configuration: RAID 0
2. Click Yes when you are prompted to save the configuration.
3. Click Yes when you are prompted to initialize the new virtual drive(s).
WebBIOS CU begins a background initialization of the virtual drives.
The following subsections contain the procedures for creating RAID drive
groups for RAID levels 0, 1, 5, 6, 00, 10, 50, and 60:
Section 4.4.3.1, "Using Manual Configuration: RAID 0"
Section 4.4.3.2, "Using Manual Configuration: RAID 1"
Section 4.4.3.3, "Using Manual Configuration: RAID 5"
Section 4.4.3.4, "Using Manual Configuration: RAID 6"
Section 4.4.3.5, "Using Manual Configuration: RAID 00"
Section 4.4.3.6, "Using Manual Configuration: RAID 10"
Section 4.4.3.7, "Using Manual Configuration: RAID 50"
Section 4.4.3.8, "Using Manual Configuration: RAID 60"
RAID 0 provides drive striping across all drives in the RAID drive group.
RAID 0 does not provide any data redundancy but does offer excellent
performance. RAID 0 is ideal for applications that require high bandwidth
but do not require fault tolerance. RAID 0 also denotes an independent
or single drive.
Note:
RAID level 0 is not fault-tolerant. If a drive in a RAID 0 drive
group fails, the whole virtual drive (all drives associated
with the virtual drive) fails.
When you select Manual Configuration and click Next, the drive group
Definition screen appears. You use this screen to select drives to create
drive groups.
1. Hold <Ctrl> while selecting two or more ready drives in the Drives
panel on the left until you have selected all desired drives for the
drive group.
Creating a Storage Configuration
4-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinkserver rd230Thinkserver td230

Table of Contents