Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in
both operating and nonoperating conditions.
Table 20 Environmental requirements
Condition
Ambient temperat-
ure
Humidity
Altitude
Shock
Vibration
Airflow

Supported SFPs

Do not use unsupported SFPs. They may not fit correctly and may void your warranty. Any port with
an unsupported SFP will automatically be disabled by switch firmware, leaving the port non-operational.
See
Supported SFP transceiver
For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN
design reference guide at the HP website:
nl
http://h18000.www1.hp.com/products/storageworks/san/documentation.html.

Supported HBAs

For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the
latest version of the HP StorageWorks SAN design reference guide at the HP website:
nl
http://h18000.www1.hp.com/products/storageworks/san/documentation.html.
Acceptable range during operation
104°F/40 °C at sea level, derated 1 C
per 1000 ft above sea level
5% to 90% relative humidity, non-con-
densing
0 to 10,000 ft (3 km) above sea level
40 G, 2mS duration
0.5 G, 10–500 Hz
47 cubic ft/minute
options, page 17 for a list of supported SFPs.
Brocade 8Gb SAN Switch for HP BladeSystem c-Class
Table 20
list the acceptable environment for
Acceptable range during non-oper-
ation
-40°C to 70°C with maximum rate of
change of 20 C /hr
50% to 80% relative humidity, non-
condensing
0 to 40,000 ft (12 km) above sea level
140 G, 2mS,
2.0 G, 5–500 Hz
None required