Power requirements

The 4Gb SAN Switch receives all necessary power from the Interconnect switch. No other
power requirement or provision exists.

Environmental requirements

To ensure proper operation, the 4Gb SAN Switch must not be subjected to environmental
conditions beyond those for which it was tested. Acceptable environmental ranges for
operating and nonoperating conditions are listed in
Table 13

Environmental requirements

Condition
Temperature
Humidity
Altitude
Vibration
Air flow
° to 35° Celsius range applies to the ambient air temperature at the air intake vents into the
The 0
Interconnect switch at the front of the BladeSystem enclosure. If the internal temperature range
exceeds the operating ranges of the components, the LEDs, error messages, and Fabric Watch alerts
indicate a problem. Enter the

Supported HBAs

For a list of HBAs supported by the external ports of the 4Gb SAN Switch, contact your local
HP Representative.
54
Technical specifications
Acceptable range during
operation
10° to 35°C (50° to 95°F)
20% to 85% RH
noncondensing, at 35°C, with
maximum gradient of 10% per
hour
3 km (0 to 10,000 ft) above
sea level
0.5 G, 5–500 Hz
Normal: provided by
enclosure
or Fabric Watch commands to view temperature status.
tempshow
Table
13.
Acceptable range during
non-operation
-30° to 60°C (-22° to 140°F)
10% to 85% RH noncondensing,
at 70° C
12 km (0 to 39,370 ft) above sea
level
2.0 G, 5–500 Hz
None required