Table A–2: Power Supply Specifications (Continued)
Specification
Harmonic distortion
BTU rating at 80%
efficiency
Inrush current
Input line protection

Environmental Requirements

Table A–3 lists the environmental ranges that are acceptable when the SAN switch
2/32 is operating, and the acceptable ranges when the switch is not operating (such as
when transporting, or storing).
Table A–3: Environmental Requirements
Condition
Temperature (operating)
Temperature (non-operating)
Humidity (operating)
Humidity (non-operating)
Altitude
(operating)
Altitude
(non-operating)
Shock
(operating)
Shock
(non-operating)
SAN switch 2/32 version 4.0.x installation guide
Value
Active power factor correction per EN61000-3-2
220 Watts / 0.8 x 3.412 BTU/Hr/Watts = 938
BTU/hr
Maximum of 15 amps for periods longer than 300
microseconds, at 50 degrees Celsius, hot or cold
start
Fused in both hot and neutral lines, using
independent fuses
Acceptable Range
°C to 40 °C
10
°C to 70 °C
-25
20% to 85% RH non condensing, at
40 °C, with maximum gradient with
10% per hour
10% to 850% RH non-condensing, at
70°C
0 to 3 km above sea level
0 to 12 km above sea level
80 G, 2.4 ms, half sine
20 G, 11 ms, half sine wave