Attaching The Inner Slide Rails To The Switch - HP A7340A - Surestore FC 1Gb/2Gb Switch 16B Installation Manual

San switch 2/16 version 3.1.x - installation guide
Hide thumbs Also See for A7340A - Surestore FC 1Gb/2Gb Switch 16B:
Table of Contents

Advertisement

Installing the SAN Switch 2/16

Attaching the Inner Slide Rails to the Switch

Use the following steps to secure each inner slide rail to the switch chassis.
1. Position the inner slide rails with the flat side against the switch, oriented in
Note:
switch slides out the rear of the HP 9000 Series Rack (as described in step 1a below).
In this way, the switch faces the aisle where exhaust air is released. Air intake and
exhaust for all components in the rack should flow in the same direction.
2. Locate three Phillips head, 8-32 x 3/16-inch screws provided in the Rack
32
Caution:
It is important to install the inner slide rails using the Phillips head,
8-32 x 3/16-inch screws supplied in the Rack Mount Kit. Installing screws
longer than 3/16-inch can damage the switch.
one of the following two ways:
HP recommends installing the SAN Switch 2/16 so that the port side of the
a. HP recommended method:
To allow the port side of the switch to slide out the rear of the rack:
Orient the inner slide rail with the end containing the lock release lever
towards the power supply end of the switch.
b. To allow the power supply side of the switch to slide out the front of the
rack:
Orient the inner slide rail with the end containing the lock release lever
towards the port end of the switch.
Mount Kit. Secure the inner slide rail to the switch, see
SAN Switch 2/16 Version 3.1.x Installation Guide
Figure
4.