How To Change The Core Pid Format - HP A7340A - Surestore FC 1Gb/2Gb Switch 16B Installation Manual

San switch 2/16 version 3.1.x - installation guide
Hide thumbs Also See for A7340A - Surestore FC 1Gb/2Gb Switch 16B:
Table of Contents

Advertisement

Installing the SAN Switch 2/16

How to Change the Core PID Format

In order for the switches to interoperate properly, all of them must have the same
Core PID format. Use these steps to change the Core PID format, if necessary.
1. If the switch is configured for zoning, type cfgDisable to disable zoning.
2. To disable the switch, type SwitchDisable and press Enter.
3. Type configure and press Enter. The following prompt displays:
4. Configure...
5. Type y at the Fabric parameters prompt,
6. Fabric parameters (yes, y, no, n): [no] y
7. Locate the line, "Core Switch PID Format: (0..1)." Type either 0 or 1 to match
8. Continue to press Enter until you have completed the configure section and
9. Type SwitchEnable and press Enter.
10. After setting the PID Format to match the the other switches in the fabric, go
11. If necessary, type cfgEnable to re-establish zoning.
Note:
and it is NOT necessary to set it again during subsequent firmware upgrades.
64
Caution:
Remember that you must change the Core PID format before
connecting fiber cables.
the SAN's existing PID format.
returned to the admin prompt.
to the
"Connecting the Switch to the
on connecting Fibre Channel cables.
Once the switch PID format is set, it is stored in the flash memory of the switch,
LAN" section on page 62 for instructions
SAN Switch 2/16 Version 3.1.x Installation Guide