Segmented E_Port Messages:
Edge Switch 2/24 Product Manager User Guide
04 Incompatible switch at the other end of the ISL.
Interop mode for this switch is set to Open Fabric mode and the switch at the
other end of the ISL is a HP switch configured for Homogeneous Fabric
mode.
05 External loopback adapter connected to the port. A
loopback plug is connected to the port and there is no diagnostic test running.
06 N_Port connection not allowed on this port. The port
type configuration does not match the actual port use. Port is configured as an
E_Port, but attaches to a node device.
07 Non-HP switch at other end of the ISL. The cable is
connected to a non-HP switch and interop mode is set to Homogeneous fabric
mode.
08 ISL connection not allowed on this port. The port type
configuration does not match the actual port use (the port is configured as an
F_Port, but attaches to a Edge Switch or Director).
10 Port binding violation - unauthorized WWN. The WWN
entered to configure port binding is not valid or a nickname was used that is
not configured through the Product Manager for the attached device.
11 Unresponsive node connected to port. Possible causes are:
— Hardware problem on switch or on a connected node where ELP frames
are not delivered, the response is not received, or a fabric login (FLOGI)
cannot be received. There may be problems in switch SBAR.
— Faulty or dirty cable connection.
— Faulty host bus adapters that do not send out FLOGI within reasonable
timeframe.
Incompatible operating parameters, such as resource allocation time-out
values (R_A_TOV) or error-detect time-out values (E_D_TOV) are
inconsistent. Refer to
information.
Duplicate domain IDs. Refer to
for more information.
Incompatible zoning configurations. Refer to sections on joining zoned
fabrics in the HP StorageWorks Edge Switch 2/24 Service Manual and the HP
StorageWorks HA-Fabric Manager User Guide for details.
Build fabric protocol error.
"Configure Fabric
Parameters" on page 108 for more
"Configure Fabric
Monitoring and Managing the Switch
Parameters" on page 108