Product Manager Messages
Table 5: StorageWorks Edge Switch 2/24 Product Manager Messages (Continued)
Port speeds cannot be
configured at a higher
rate than the
director/switch speed.
Product Manager error
<number>.
Product Manager
instance is currently
open.
R_A_TOV must be
greater than E_D_TOV.
Resource is unavailable.
SANtegrity Feature not
installed. Please contact
your sales representative.
Send firmware failed.
SNMP trap address not
defined.
Stop diagnostics failed.
The test is already
running.
196
Message
This displays when you
configure a port to 2
GB/sec and the switch
speed is set to 1 Gb/sec.
The switch Product
Manager encountered
an internal error and
cannot continue.
A Product Manager
window is currently
open.
R_A_TOV must be
greater than E_D_TOV.
The specified operation
cannot be performed
because the product is
unavailable.
The user selected Switch
Binding from the
Configure menu, but the
optional SANtegrity
Binding feature is not
installed.
Send firmware operation
has failed.
An SNMP trap address
must be defined if a
community name is
defined.
Diagnostics for the port
was not running and the
Stop was selected on the
Port Diagnostics dialog
box. Diagnostics quit for
the port for some reason,
but the Stop button
remains enabled.
Description
Edge Switch 2/24 Product Manager User Guide
Action
Set the port speed to 1
Gb/sec in the Configure
Operating Parameters
dialog box.
Report the problem to
support personnel.
N/A. Informational
message.
Change one of the values
so that R_A_TOV is greater
than E_D_TOV.
Verify that the HAFM
server-to-product link is up.
If the link is up, the HAFM
server may be busy. Try the
operation again later.
Install the SANtegrity key
through the Configure
Feature Key dialog box
before using Switch Binding
features.
Retry the operation. If the
condition persists, contact
support personnel.
Define an SNMP address.
Verify port operation. Retry
diagnostics for port and
select Stop from the dialog
box. If problem persists,
contact your service
representative.