Table 1. Abbreviated list of firmware error codes (continued)
Error code
Failing device or problem found
25C0xx yy
DIMM failure:
where xx and yy are:
xx
01
02
04
10
12
14
20
21
22
24
40
41
42
44
88
74
BladeCenter JS20 Type 8842: Installation and User's Guide
Description
DIMM4 missing
DIMM3 unsupported and
DIMM4 missing
DIMM3 failed and DIMM4
missing
DIMM3 missing
DIMM3 unsupported
DIMM3 failed
DIMM3 missing and DIMM4
unsupported
DIMM4 unsupported
DIMM3 and DIMM4
unsupported
DIMM3 failed and DIMM4
unsupported
DIMM3 missing and DIMM4
failed
DIMM4 failed
DIMM4 failed and DIMM3
unsupported
DIMM3 and DIMM4 failed
DIMM3 and DIMM4
mismatch
Suggested action
Note: For additional information about DIMMs, see
"Installing memory modules" on page 24.
1. Make sure that all the DIMMs in the blade server are
supported. Replace all the unsupported DIMMs.
2. Make sure that the DIMMs are installed in matched
pairs. If the DIMMs are not installed in matched pairs,
reinstall them in matched pairs.
3. Make sure that the DIMMs are correctly seated. If
necessary, reseat the DIMMs.
4. Restart the blade server.
5. Remove and reinstall the DIMMs one at a time until
the failing DIMM is isolated. Replace the defective
DIMM.
If the problem remains, replace the system-board
assembly. Contact a service support representative for
assistance.

Advertisement