Table 1. Abbreviated list of firmware error codes (continued)
Error code
Failing device or problem found
20EE000B
The blade server could not find the
operating system among the devices
in the boot list.
Note: The startup sequence is also
known as the boot list.
20EE000F
Unable to find the package node.
20EE0010
Unable to process the root vpd
method.
20EE0011
Unable to process the vpd method.
20EE0012
Unable to process the
mem-dimm-vpd method.
20EE0015
The blade server failed to read the
VPD startup path field value.
20EE0016
The blade server failed to update the
VPD with the new startup path field
value.
20EE0020
The environment variable,
startup-device, exceeds the
maximum number of characters.
20EE0021
The environment variable,
startup-device, contains more than
five entries.
20EE0022
The environment variable,
startup-device, contains an entry that
exceeds 255 characters in length.
20EE0023
The blade server failed to set the
operating-system boot list from the
management-module boot list.
68
BladeCenter JS20 Type 8842: Installation and User's Guide
Suggested action
v If you have not installed an operating system on the
blade server, install it now.
v If you have installed an operating system on the blade
server, make sure that the startup sequence contains at
least one device with a valid operating-system startup
image.
v If the startup device is a SAN device, also see error
code 20A80100.
If the problem remains, have the blade server serviced.
Contact a service support representative for assistance.
Perform the system checkout procedure. See "System
checkout" on page 48.
Perform the system checkout procedure. See "System
checkout" on page 48.
Perform the system checkout procedure. See "System
checkout" on page 48.
Perform the system checkout procedure. See "System
checkout" on page 48.
1. Make sure that the boot list in the management
module is correct.
2. Perform the system checkout procedure. See "System
checkout" on page 48.
1. Make sure that the boot list in the management
module is correct.
2. Perform the system checkout procedure. See "System
checkout" on page 48.
1. Make sure that the boot list in the management
module is correct.
2. Perform the system checkout procedure. See "System
checkout" on page 48.
1. Make sure that the boot list in the management
module is correct.
2. Perform the system checkout procedure. See "System
checkout" on page 48.
1. Make sure that the boot list in the management
module is correct.
2. Perform the system checkout procedure. See "System
checkout" on page 48.
1. Make sure that the boot list in the management
module is correct.
2. Check the http://www.ibm.com/support Web site for
firmware updates for the management module, service
processor, and blade server. Apply the latest updates,
if they are available.
3. If updates are not available, contact your system
administrator for assistance.
If the problem remains, call for service.