Table 1. Abbreviated list of firmware error codes (continued)
Error code
Failing device or problem found
20D008 xx
Failure to access VPD data.
Where xx is:
xx
0E, 0F
10, 11
16, 17
1E
20D00900
The blade server failed to generate a
UUID value.
20D00901
The blade server failed to
communicate with the service
processor.
20D00902
The blade server is starting from the
permanent firmware code page
(PERM image).
20D00903
The blade server failed to find the
/openprom package. This is most
likely a software error.
20D1000A
The blade server failed to send the
startup-failure message to the service
processor.
20D10004
The blade server failed to locate
service processor device-tree node.
20D10005
The blade server failed to restart.
20D10006
The blade server failed to restart a
partition.
20D10007
Partition firmware error before stdout
ready.
20D10010
Stack underflow from the Fibre
Channel adapter.
Suggested action
Perform the system checkout procedure. See "System
checkout" on page 48.
Description
Machine type or
model
System serial
number
Universal unique
identifier (UUID)
Startup (boot)
mode
1. Replace the memory in the blade server.
2. Replace the system-board assembly. Contact a
service support representative for assistance.
Have the blade server serviced. Contact a service support
representative for assistance.
If the blade server was set to start from the permanent
firmware code page (PERM image), this is an
informational message.
If it was not, this indicates that the blade server was
unable to start from the temporary firmware code page
(TEMP image).
Go to "Recovering the system firmware code" on page 84.
Have the blade server serviced.
Have the blade server serviced. Contact a service support
representative for assistance.
Perform the system checkout procedure. See "System
checkout" on page 48.
Perform the system checkout procedure. See "System
checkout" on page 48.
Perform the system checkout procedure. See "System
checkout" on page 48.
Perform the system checkout procedure. See "System
checkout" on page 48.
Perform the system checkout procedure. See "System
checkout" on page 48.
1. Check the http://www.ibm.com/support Web site for
microcode updates for the Fibre Channel adapter.
Apply the latest update, if one is available.
2. If an update is not available, contact a system
administrator for assistance.
3. Perform the system checkout procedure. See "System
checkout" on page 48.