Table 1. Abbreviated list of firmware error codes (continued)
Error code
Failing device or problem found
25A80210
Setenv/$Setenv parameter error;
name contains a null character.
25A80211
Setenv/$Setenv parameter error;
value contains a null character.
25A80998
NVRAMRC script evaluation error.
25A80999
NVRAMRC script evaluation error;
stack unbalanced on completion.
25000000
The blade server failed to set the
Write Delay (WRDLY) bit in the
memory controller register.
25C00000
No DIMMs were detected.
Suggested action
If the problem remains, replace the battery in the blade
server. For additional information, see the Hardware
Maintenance and Troubleshooting Guide.
Note: After you replace the battery, you must reset the
system date and time through the operating system that
you installed.
If the problem still remains, replace the system-board
assembly. Contact a service support representative for
assistance.
If the problem remains, replace the battery in the blade
server. For additional information, see the Hardware
Maintenance and Troubleshooting Guide.
Note: After you replace the battery, you must reset the
system date and time through the operating system that
you installed.
If the problem still remains, replace the system-board
assembly. Contact a service support representative for
assistance.
Perform the following steps to remove the NVRAMRC
script:
1. Boot to the open firmware prompt.
2. Enter the following command:
0 0 " nvramrc" $setenv
If the problem remains, contact your system administrator
for assistance.
This is a firmware debug environment error. No action is
required. No component replacement is required.
If the problem remains, have the blade server serviced.
1. Start from the PERM flash image to reflash the TEMP
image for recovery. See "Recovering the system
firmware code" on page 84.
2. If the problem remains, replace the blade server.
Contact a service support representative for
assistance.
Note: For additional information about DIMMs, see
"Installing memory modules" on page 24.
1. Make sure that the DIMMs are correctly seated. If
necessary, reseat the DIMMs.
2. Restart the blade server.
3. Perform the system checkout procedure. See "System
checkout" on page 48.
If the problem remains, replace the system-board
assembly. Contact a service support representative for
assistance.
Chapter 7. Solving problems