Table 3. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 9 "Parts listing, ThinkServer RD210 Type 3795, 3796, 3818, and 3819" on page 143 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
201-802-xxx Memory
201-803-xxx Memory
201-804-xxx Memory
State
Description
Memory
Aborted Test
Test
canceled:
the end
address in
the E820
function is
less than 16
MB.
Memory
Aborted Test
Test
canceled:
could not
enable the
processor
cache.
Memory
Aborted Test
Test
canceled:
the memory
controller
buffer
request
failed.
Action
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that all DIMMs are enabled in the
Setup utility.
4. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component.
5. Run the test again.
6. If the failure remains, go to
http://www.lenovo.com/support for
more troubleshooting information.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component.
4. Run the test again.
5. If the failure remains, go to
http://www.lenovo.com/support for
more troubleshooting information.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component.
4. Run the test again.
5. If the failure remains, go to
http://www.lenovo.com/support for
more troubleshooting information.
Chapter 5
47
.
Diagnostic