Lenovo ThinkServer RD210 Hardware Maintenance Manual page 43

Hardware maintenance manual
Hide thumbs Also See for ThinkServer RD210:
Table of Contents

Advertisement

Table 3. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 9 "Parts listing, ThinkServer RD210 Type 3795, 3796, 3818, and 3819" on page 143 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
166-813-xxx IMM
166-814-xxx IMM
State
Description
IMM I2C
Aborted IMM I2C test
Test
stopped:
cannot
return the
number of
requested
data bytes.
IMM I2C
Aborted IMM I2C test
Test
stopped:
requested
sensor,
data, or
record is not
present.
Action
1. Turn off the system and disconnect it from
the power source. You must disconnect the
system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the
power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to:
http://www.lenovo.com/support
5. Make sure that the IMM firmware is at the latest
level. The installed firmware level is shown in
the DSA event log in the Firmware/VPD section
for this component.
6. Run the test again.
7. If the failure remains, go to
http://www.lenovo.com/support for
more troubleshooting information.
1. Turn off the system and disconnect it from
the power source. You must disconnect the
system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the
power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to:
http://www.lenovo.com/support
5. Make sure that the IMM firmware is at the latest
level. The installed firmware level is shown in
the DSA event log in the Firmware/VPD section
for this component.
6. Run the test again.
7. If the failure remains, go to
http://www.lenovo.com/support for
more troubleshooting information.