Removing and installing the microprocessor 2 air baffle

To remove and install the microprocessor 2 air baffle, complete the steps in this section.

Removing the microprocessor 2 air baffle

To remove the microprocessor 2 air baffle, complete the following steps:
1. Read the safety information in Chapter 2 "Safety information" on page 3 and "Installation guidelines"
on page 67.
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables, if
necessary; then, remove the cover (see "Removing and replacing the cover" on page 72).
3. Lift the air baffle
2
up, making sure that the tab
power-supply cage; then, remove it from the server and set it aside.
Attention: For proper cooling and airflow, replace the air baffle before you turn on the server. Operating
the server with the air baffle removed might damage server components.

Installing the microprocessor 2 air baffle

To install the microprocessor 2 air baffle (if you removed it), complete the following steps:
1. Read the safety information in Chapter 2 "Safety information" on page 3 and "Installation guidelines"
on page 67.
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables, if
necessary.
3. Align the microprocessor 2 air baffle tab with the hole on the side of the power-supply cage; then insert
the tab into the hole on the cage (make sure that the front end of the air baffle is lined up with the blue
press point tab on the left of fan 6). Press the air baffle down until the it is securely seated.
4. Install the cover see "Removing and replacing the cover" on page 72).
5. Reconnect the power cords and any cables that you removed.