Table 3. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 9 "Parts listing, ThinkServer RD210 Type 3795, 3796, 3818, and 3819" on page 143 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
215-801-xxx Optical
Drive
State
Description
• Verify
Aborted Unable to
Media
communicate
Installed
with the
device
• Read/
driver.
Write
Test
• Self-Test
Messages
and
actions
apply to all
three tests.
Action
1. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to:
http://www.lenovo.com/support
2. Run the test again.
3. Check the drive cabling at both ends for loose
or broken connections or damage to the cable.
Replace the cable if it is damaged.
4. Run the test again.
5. For additional troubleshooting information, see
the Installation and User Guide.
6. Run the test again.
7. Make sure that the system firmware is
at the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component.
8. Run the test again.
9. Replace the CD/DVD drive.
10. If the failure remains, go to
http://www.lenovo.com/support for
more troubleshooting information.