11. Reconnect the power cord and any cables that you removed.
12. Replace the cover (see "Removing and replacing the cover" on page 72).
13. Turn on the peripheral devices and the server.
DIMM installation sequence
Memory mirroring
Installation steps

Removing and installing the IBM ServeRAID-BR10i SAS/SATA Controller

To remove and install the IBM ServeRAID-BR10i SAS/SATA Controller, complete the steps in this section.

Removing the IBM ServeRAID-BR10i SAS/SATA Controller

To remove the IBM ServeRAID-BR10i SAS/SATA controller from the system board, complete the following
steps:
1. Read the safety information in Chapter 2 "Safety information" on page 3 and "Installation guidelines"
on page 67.
2. Turn off the server and peripheral devices and disconnect the power cords.
Note: When you disconnect the power source from the server, you will lose the ability to view the LEDs
because the LEDs will not be lit with the power source removed. Before disconnecting the power source,
make a note of which LEDs are lit, including the LEDs that are lit on the operation information panel, the
EasyLED panel, and LEDs that are lit inside the server on the system board; then, see "EasyLED" on
page 20 for information on how to solve the problem.
3. Remove the cover (see "Removing and replacing the cover" on page 72).
4. Disconnect the signal cables that are attached to the drive backplane from the connectors on the
controller.
5. Grasp the SAS/SATA controller near the end next to the power-supply cage and press the black plastic
tab (next to the power supply) that is holding the controller in place toward the power supply.
6. Pull up on the SAS/SATA controller until the RAID riser card assembly disengages from the connector
on the system board.
1
USB embedded connector
2
RAID controller connector
3
Riser card error LED
4
SAS/SATA RAID riser card
7. Grasp the SAS/SATA controller and pull it out of the connector on the RAID riser card assembly.
.
Chapter 7