Removing And Installing The Sas/Sata Raid Riser-Card Assembly; Removing The Sas/Sata Raid Riser-Card Assembly - Lenovo ThinkServer RD210 Hardware Maintenance Manual

Hardware maintenance manual
Hide thumbs Also See for ThinkServer RD210:
Table of Contents

Advertisement

1
Fan tabs
2
Fan connector on the system
board
3
Fan 1
4
Fan 2
5
Fan 3
Attention: To ensure proper operation, replace a failed fan as soon as possible.
5. Orient the new fan over the fan slot in the fan assembly bracket so that the fan cable connector aligns
with the fan connector on the system board.
6. Insert the fan into the fan slot in the fan assembly bracket and press it down until it is seated correctly in
the slot and the fan cable is seated correctly in the fan connector on the system board.
If you have other options to install or remove, do so now. Otherwise, go to "Completing the installation" on
page 130.

Removing and installing the SAS/SATA RAID riser-card assembly

To remove and install the SAS/SATA RAID riser-card assembly, complete the steps in this section.

Removing the SAS/SATA RAID riser-card assembly

To remove the SAS/SATA RAID riser-card assembly, complete the following steps:
1. Read the safety information in Chapter 2 "Safety information" on page 3 and "Installation guidelines"
on page 67.
2. Turn off the server and peripheral devices and disconnect all power cords; then, remove the cover (see
"Removing and replacing the cover" on page 72).
3. Disconnect the cables from the connectors on the SAS/SATA controller; then, grasp the controller and
pull it out of the connector on the RAID riser-card assembly.
4. Remove the flash device from the SAS/SATA RAID riser card
102
ThinkServer RD210 Hardware Maintenance Manual
6
Fan 4
7
Fan 5
8
Fan 6
9
Fan connector
10
Fan (side view)
1
, if one is installed.