Setup Menu
Auxiliary Output
Auxiliary Output 1
Auxiliary Output 2
Tamper
ID Refused
Duress
Try Again
F1 Key
F2 Key
On Battery Backup
Set Reader
The Set Reader Mode command allows a HandReader to be set as the Master
Mode
HandReader in a HandReader network. All user enrollment is done through the
Master HandReader. The Master HandReader automatically downloads user data
to all remote HandReaders on the network. The Reader Mode does not need to
be set for stand-alone HandReaders and PC networks.
In HandReader networks, one HandReader must be set as a Master HandReader
and all remaining HandReaders must be set as Remote HandReaders. The
default Reader Mode is Remote mode. Reader Mode does not apply to stand-
alone HandReaders or HandReaders in a PC network (the HandReader should be
left in its default value).
All remote HandReaders on a HandReader network must have a unique address.
NOTE
Refer to the Set Reader Address section on page 52.
The HandReader's display can tell you if a reader has been configured as a
Master Reader or a Remote Reader.
A Master Reader has double-dashes surrounding the "READY" text.
Page 54
Table 10: Auxiliary Output Choices
Auxiliary 1 switched to ground
Auxiliary 2 switched to ground
HandReader opened, shaken, or removed.
User not verified after allowed number of tries.
User entered the duress code digit.
User rejected.
F1 key pressed.
F2 key pressed.
AC power failure, HandReader switched to battery power.