Handle assembly

Before you begin:
v Read "Safety information" on page 129
v Review the information in "System reliability considerations" on page 33
To remove the handle cap, complete the following steps:
1. Turn off the server, if it is on.
2. Unplug the server, and disconnect the power cord; then, disconnect all external
3. Use a flathead screwdriver to gently press in and down on the tabs located on
4. Lift up on the handle cap to separate it from the handle support.
5. Turn the system back to the tower-orientation; then, remove the top handle.
To remove the handle support, complete the following steps:
1. Turn off the server, if it is on.
2. Unplug the server, and disconnect the power cord; then, disconnect all external
3. Firmly grasp the handle support, and slide it away from the front bezel.
4. Lift up on the handle support to remove it from the slots in the top of the
To install the handle assembly, reverse the steps.
cables.
the interior side wall of the handle.
Tab locations
a. Carefully use a flat-blade screwdriver to push in the tabs inside the plastic
cover on the top of the system; then, remove the plastic cover. Store the
cover for possible future use.
b. Grasp the metal handle and slide it toward the rear of the server to remove
it from your server. Store the metal handle for possible future use.
cables.
chassis.