IBM 8649 - Eserver xSeries 225 Maintenance And Troubleshooting Manual page 123

Hardware maintenance manual
Hide thumbs Also See for 8649 - Eserver xSeries 225:
Table of Contents

Advertisement

Note: See "System replaceable units" on page 122 to determine which components should be replaced by a field
service technician.
Error code/symptom
5962
(IDE CD-ROM drive configuration error)
8603
(Pointing-device error)
00012000
(Machine check architecture error.)
00019502
(Microprocessor 1 failed)
00180100
(No room for PCI option ROM)
00180200
(No more I/O space available for PCI
adapter.)
00180300
(No more memory above 1MB for PCI
adapter.)
00180400
(No memory below 1 MB for PCI adapter.)
00180500
(PCI option ROM checksum error.)
00180600
(PCI device BIST failure. PCI bridge error.)
00180700
(PCI device not responding.)
00181000
(General PCI error)
I9990650
(AC power has been restored)
FRU/action
1. Run the Configuration/Setup Utility program.
2. CD-ROM drive.
3. CD-ROM power cable.
4. IDE cable.
5. System board.
6. Battery.
1. Pointing device.
2. System board
1. Microprocessor.
2. System board.
1. Microprocessor.
2. System board
1. Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
1. PCI adapter.
2. System board.
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
1. PCI adapter.
2. System board.
1. Adapter
2. System board
1. Check cable.
2. Check for interruption of power.
3. Power cable.
Chapter 6. Symptom-to-FRU index
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 225 types 8649

Table of Contents