Note: See "System replaceable units" on page 122 to determine which components should be replaced by a field
service technician.
Error code/symptom
604
(Diskette drive error)
662
(Diskette drive configuration error)
962
(Parallel port configuration error)
1162
(Serial port configuration error)
11XX
(System board serial port 1 or 2 error)
1762
(Hard drive configuration error, IDE only.)
178X
(Hard drive error, IDE only.)
1800
(No more hardware interrupt available for
PCI adapter.)
1801
(No more ROM space available for PIC
adapter.)
1962
(Drive does not contain a valid boot
sector)
2462
(Video configuration error)
112
IBM xSeries 225 Types 8649: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
System board
1. Run the Configuration/Setup Utility program.
2. System board.
1. Hard disk drive.
2. Hard disk cables.
3. Run the Configuration/Setup Utility program.
4. System board.
1. Hard disk cables
2. Hard disk adapter
3. Hard disk drive
4. System board
1. Run the Configuration/Setup Utility program.
2. Remove adapter.
1. Run the Configuration/Setup Utility program.
2. Remove adapter.
3. Disable the adapter BIOs and run the Configuration/Setup Utility
program.
1. Verify that a startable operating system is installed.
2. Run diagnostics.
3. Hard disk drive.
4. SCSI backplane.
5. Cable.
6. System board.
System board.