IBM 8649 - Eserver xSeries 225 Maintenance And Troubleshooting Manual page 115

Hardware maintenance manual
Hide thumbs Also See for 8649 - Eserver xSeries 225:
Table of Contents

Advertisement

Error Code/Symptom
165-060-000 (Service Processor: RSA may
be busy)
165-198-000 (Service Processor: Aborted)
165-201-000 (Service Processor: Failed)
165-330-000 (Service Processor: Failed)
165-342-000 (Service Processor: Failed)
180-XXX-000 (Diagnostics LED failure)
180-XXX-001 (Failed Front LED panel test)
180-XXX-002 (Failed Diagnostics LED
panel test)
180-XXX-003 (Failed System Board LED
test)
180-XXX-005 (Failed SCSI Backplane LED
test)
201-XXX-0NN (Failed Memory test, see
"Installing memory modules" on page 55).
202-XXX-001 (Failed System Cache test)
202-XXX-002 (Failed System Cache test)
206-XXX-000 (Failed Diskette Drive test)
FRU/Action
1. Rerun the diagnostic test.
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
4. System Board.
.
1. Rerun the diagnostic test.
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
4. System Board.
1. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
2. System Board.
Update to the latest ROM diagnostic level, and retry.
1. Ensure latest firmware levels for ASM and BIOS.
2. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
3. System Board.
Run Diagnostic LED test for the failing LED.
Information LED Panel
System board
System board
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
1. DIMM Location slots 1-4 where NN = DIMM location.
Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN 4=DIMM 4
2. System Board
1. Microprocessor 1
2. System Board
1. Microprocessor 2
2. System Board
1. Try test with another diskette.
2. Cable.
3. Diskette Drive.
4. System Board.
Chapter 6. Symptom-to-FRU index