Loading the StorCon Program Under Windows NT/2000

1. Ensure that Windows has been configured to meet all the requirements of the RAID Software
Suite setup.
2. If the Intel RAID Controller SRCMR has not been installed into the computer, then install it
before continuing. Consult Chapter 2 for details when installing the Intel RAID Controller
SRCMR. After the controller has been installed, go to step 3.
3. Log into Windows using a user account with administrative rights.
4. Insert the RAID Software Suite CD-ROM in the CD-ROM drive. Select Install to install
StorCon.
5. License Agreement - Click Yes after reading to agree.
6. Information - Click Next when ready to continue.
7. Select Components - Select one of the following (Remote or Local administration):
 Local Administration
Select components that you wish to install or select the default selections (Windows NT,
see Figure 10) (Windows 2000, see Figure 11). Click Next to continue the installation.
 Remote Administration
Select Remote Storage Console under Management Tools branch (Windows NT, see Figure
10) (Windows 2000, see Figure 11). Click Next to continue the installation.
8. Choose the Destination Location - Use the default directory for installation, click Next.
9. Select the Program Folder - Use default Program Group, click Next.
10. After the file copy completes, restart the computer to complete the installation for NT. For
Windows 2000 where the OS is installed on a non-RAID device, continue with step 12.
11. Windows 2000 Only: Reboot the server and log into Windows. If your OS is not on a RAID
device, you will see a pop up message, Found New Hardware. The OS has detected the RAID
management driver.
12. Continue by clicking Next. The OS will attempt to locate the drivers for this device.
13. Do not let the OS locate the driver. When prompted, uncheck the boxes for Floppy and
CD-ROM. Place a check in the box to Specify Location.
14. Type the following location: c:\program files\raid software suite\drivers. Note: this is the
default installation location. If you have not chosen the default during installation, type in that
location. This is important to keep the Found New Hardware pop up from appearing each time
you log into Windows.
15. Finish the installation and reboot.
This completes the installation procedure for Windows.