Chapter A
Troubleshooting
Analysis Engine is Busy
After you reimage a sensor, Analysis Engine is busy rebuilding Regex tables and does not respond to
new configurations. You can check whether Analysis Engine is busy by using the show statistics
virtual-sensor command. You receive the following error message if Analysis Engine is busy:
sensor# show statistics virtual-sensor
Error: getVirtualSensorStatistics : Analysis Engine is busy rebuilding regex tables. This
may take a while.
sensor#
When Analysis Engine is busy rebuilding Regex tables, you receive an error message if you try to update
a configuration, for example, enabling or retiring a signature:
sensor# configure terminal
sensor(config)# service sig sig0
sensor(config-sig)# sig 2000 0
sensor(config-sig-sig)# status enabled
sensor(config-sig-sig)# status
sensor(config-sig-sig-sta)# enabled true
sensor(config-sig-sig-sta)# retired false
sensor(config-sig-sig-sta)# exit
sensor(config-sig-sig)# exit
sensor(config-sig)# exit
Apply Changes?[yes]:
Error: editConfigDeltaSignatureDefinition : Analysis Engine is busy rebuilding regex
tables. This may take a while.
The configuration changes failed validation, no changes were applied.
Would you like to return to edit mode to correct the errors? [yes]: no
No changes were made to the configuration.
sensor(config)#
If you try to get the virtual sensor statistics immediately after you boot a sensor, you receive an error
message. Although the sensor has rebuilt the cache files, the virtual sensor is not finished initializing.
sensor# show statistics virtual-sensor
Error: getVirtualSensorStatistics : Analysis Engine is busy.
sensor#
When you receive the errors that Analysis Engine is busy, wait a while before trying to make
configuration changes. Use the show statistics virtual-sensor command to find out when Analysis
Engine is available again.
Connecting the IPS 4240 to a Cisco 7200 Series Router
When an IPS 4240 is connected directly to a 7200 series router and both the IPS 4240 and the router
interfaces are hard-coded to speed 100 with duplex Full, the connection does not work. If you set the
IPS 4240 to speed Auto and duplex Auto, it connects to the router but only at speed 100 and duplex Half.
To connect correctly at speed 100 and duplex Full, set the interfaces of both the IPS 4240 and the router
to speed Auto and duplex Auto. Also, if either interface is hard-coded, you must make the connection
using a crossover cable.