Changing The Volume Id; What's Next - Novell OPEN ENTERPRISE SERVER 2 SP 2 - CLUSTER SERVICES 1.8.7 FOR LINUX Manual

Table of Contents

Advertisement

For information, see
Section 9.11, "Deleting Cluster Resources," on page

10.12 Changing the Volume ID

Novell Cluster Services supports NCP client access to cluster-enabled NSS volumes by using a
unique volume ID to mount the volume in the cluster. The volume ID is used by an NCP client only
for automatic reconnects to the volume after failover or migration of a cluster resource.
Valid volume ID values are 0 to 254 (up to 255 mounted volumes per server). When you create a
new volume on a cluster-enabled pool, Cluster Services automatically assigns it a volume ID that is
unique in the entire cluster and writes the value to the cluster resource load script for the pool.
Values start at 254 for the first volume in the cluster and decrease for each new volume.
In older operating systems, there was a mounted volume limit of 64 volumes (values 0 to 63). Some
older applications might have hardcoded the old maximum limit of 64 mounted volumes, and might
not be able to handle volume IDs greater than 63. You can use the Clusters plug-in to iManager to
modify the volume ID in the scripts for a given cluster resource in order to specify a value that
works for the application.
Changing the volume ID does not affect the ability to log in to, back up, or access the data. However,
there is a brief disruption of service as the cluster resource is offlined and onlined to apply the script
changes. If you modify the volume ID for a volume in the cluster resource scripts, make sure to do
the following:
Volume IDs that you manually assign must be unique across every volume on all servers in
cluster.
After the value is changed, you must offline and online the cluster resource for the volume in
order to mount the volume with its new volume ID.
After the volume is mounted with its new ID, the clients must log out and log in to the volume
in order to reconnect to the volume with its new volume ID. Automatic reconnection after
cluster resource failovers or migrations occurs properly after this one-time reset.
Some clients might cache the volume IDs. To reset the cached value, the client must be
rebooted and reconnected to the volume.
After the volume is mounted with its new ID, if the backup software is running on a client
connection, you might need to restart the backup to reconnect to the volume with its new
volume ID. Automatic reconnection after cluster resource failovers or migrations occurs
properly after this one-time reset.

10.13 What's Next

For information on managing the cluster, see
Chapter 8, "Managing Clusters," on page
Configuring Cluster Resources for Shared NSS Pools and Volumes 155
128.
97.

Advertisement

Table of Contents
loading

Table of Contents