Determining Storage System Status and Verifying
Faults
The System Summary page shows you the overall status of the storage system.
To view storage system status:
1. Select Monitor > Status > Status Summary.
2. Check the status icon at the upper left corner of each panel.
A green icon
operating normally.
A red icon with an exclamation point
associated with that panel has a fault and is operating in a degraded state or is
offline.
Figure 7-1 Status Summary Page with a Fault Identified by Status Icons
3. Review each panel that has a fault icon.
4. Look for red text in the panels.
Red text indicates where the fault is occurring. In Figure 7-1 for example, the panels
indicate a fault related to controller module B.
5. To gather more details regarding the failure, click linked text next to the fault icon.
The associated status page is displayed.
indicates that components associated with that panel are
indicates that at least one component
Chapter 7 Troubleshooting Using SMU
197