HP 2000fc Reference Manual page 283

Modular smart array
Hide thumbs Also See for 2000fc:
Table of Contents

Advertisement

TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code
Event Type
90
Informational
95
Critical
96
Informational
100
Informational
101
Informational
103
Informational
104
Informational
105
Informational
106
Informational
Description
The partner controller does not have a
mirrored configuration image for the
current controller, so the current
controller's local flash configuration
is being used. This event is expected
if the other controller is new or its
configuration has been cleared.
Both controllers in an active-active
configuration have the same serial
number. Non-unique serial numbers
can cause system problems; for
example, vdisk ownership and
WWNs are determined by serial
number.
Pending configuration changes that
take effect at startup were ignored
because customer data might be
present in cache.
During active-active operation, an
event (potential error) occurred while
communicating with the EMP, which
reports SES data.
An update of EMP data has been
triggered. This event is for internal
use only.
Volume name change is complete.
Volume size change is complete.
Volume LUN change is complete.
A volume has been added.
Recommended Action
A service technician must examine
both controller serial numbers and
change at least one of them.
If the requested configuration
changes did not occur, make the
changes again and then use a user-
interface command to shut down or
restart the controller.
Appendix E Event Codes
283

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2000 series

Table of Contents