TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code
Event Type
39
Warning
40
Critical
41
Informational
43
Informational
44
Warning
278
HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008
Description
The sensors monitored a temperature
or voltage in the warning range.
The sensors monitored a temperature
or voltage in the failure range.
A vdisk spare has been added.
A vdisk has been deleted.
The controller contains dirty cache
data for the specified volume but the
corresponding disk drives are not
online.
Recommended Action
• Check that the storage system's
fans are running.
• Check that the ambient
temperature is not too warm. The
enclosure operating range is
41° F to 104° F (5° C to 40° C).
• Check for any obstructions to the
airflow.
• If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
• Check that the storage system's
fans are running.
• Check that the ambient
temperature is not too warm. The
enclosure operating range is
41° F to 104° F (5° C to 40° C).
• Check for any obstructions to the
airflow.
• If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
• Determine the reason that the
drives are not online.
• If an enclosure is down,
determine corrective action.
• If the virtual disk is no longer
needed, you can clear the orphan
data; this will result in lost data.