To view expander status information:
1. Select Monitor > Status > Advanced Settings > Expander Status.
2. Select an enclosure.
The information is displayed in three panels.
The Enclosure Details panel shows the following information about the selected
enclosure:
Name – Name assigned to the enclosure.
■
Vendor – Enclosure manufacturer.
■
Location – Enclosure location, if set.
■
Status – Specifies whether the enclosure is OK or has an error.
■
Misc – Enclosure ID, which is 0 for a controller enclosure and increments from 1
■
for attached drive enclosures.
World Wide Name – Enclosure node World Wide Name.
■
Model – Enclosure model number.
■
Rack:Position – Assigned rack number and position of the enclosure within the
■
rack, or 0:0 if not set. Position 1 is the top and 16 is the bottom.
Firmware Version – Version of the EC, which performs SES functions.
■
The Phy Isolation Details panel shows the following settings for each EC:
Phy Isolation – Shows whether all PHYs in the expander are monitored for faults
■
and automatically isolated if too many faults are detected. The default is Enabled.
Monitoring Period – Specifies how often the EC checks each PHY and
■
determines whether it should be isolated. The default is 100 milliseconds.
The Expander Controller Phy Detail panel shows the following information about
each PHY in each EC:
Status – Specifies one of the following:
■
■
■
■
■
■
168
HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008
OK – The PHY is healthy.
Error – The PHY experienced an unrecoverable error condition or received an
unsupported PHY status value.
Disabled – The PHY has been disabled by a Diagnostic Manage user or by the
system.
Non-Critical – The PHY is not coming to a ready state or the PHY at the other
end of the cable is disabled.
Not Used – The module is not installed.