HP 2000fc Reference Manual page 234

Modular smart array
Hide thumbs Also See for 2000fc:
Table of Contents

Advertisement

Table A-1 FA MIB 2.2 Objects, Descriptions, and Values (Continued)
Object
connUnitSensorMessage
connUnitSensorType
connUnitSensor
Characteristic
connUnitPortTable
connUnitPortUnitId
connUnitPortIndex
connUnitPortType
connUnitPortFCClassCap
connUnitPortFCClassOp
234
HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008
Description
Description the sensor status as a
message
Type of component being
monitored by this sensor
Characteristics being monitored
by this sensor
Includes the following objects as
specified by the FA MIB2.2 Spec
connUnitId of the connectivity
unit that contains this port
Unique value for each
connUnitPortEntry between
1 and connUnitNumPorts
Port type
Bit mask that specifies the classes
of service capability of this port.
If this is not applicable, returns all
bits set to zero.
Bit mask that specifies the classes
of service that are currently
operational. If this is not
applicable, returns all bits set to
zero.
Value
connUnitSensorName
followed by the appropriate
sensor reading.
Temperatures display in
both Celsius and
Fahrenheit; for example,
CPU Temperature
(Controller Module A):
48C 118F). Reports "Not
installed" or "Offline" if
data is not available.
See "External Details for
connUnitSensorTable" on
page 239
See "External Details for
connUnitSensorTable" on
page 239
Same as connUnitId
Unique value for each port,
between 1 and the number
of ports
not-present[3], or n-port[5]
for point-to-point topology,
or l-port[6]
Fibre Channel ports return
8 for class-three
Fibre Channel ports return
8 for class-three

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2000 series

Table of Contents