Module Status

You can view summary status information for each controller module and all
enclosures in the storage system. More detail is available on other Monitor pages.
To view module status:
Select Monitor > Status > Module Status.
The Rear Panel Chassis View shows the back of the controller enclosure and the
current status of power-and-cooling modules and controller modules. Failed
modules are displayed in red.
The following information is displayed for each controller module:
Present? – Yes if installed or No if not installed. Click Yes to see software and
hardware version details on the Controller Versions page.
Primary Status – One of the following:
Online – The module is present and operating correctly.
Offline – The module is either not installed or has been taken out of service by
the system or by user request.
Failed – A hardware or system error has been detected and the module is not
functioning correctly.
Secondary Status – Additional status information.
Serial Number – Controller module serial number.
HW Version – Controller module hardware version and CPLD version.
Summary information is displayed about the status of system enclosures. Any
abnormal conditions are displayed, indicating the enclosure where the problem is,
the element within the enclosure that is reporting the condition, and the status of the
element. The following categories are monitored:
Power Supplies – Indicates the presence of critical or warning conditions in any
enclosure power supply.
Cooling – Indicates the presence of critical or warning conditions in any cooling
fan.
Temperature Sensors – Indicates the presence of critical or warning conditions
detected by an enclosure temperature sensor.
Voltage Sensors – Indicates the presence of critical or warning conditions
detected by an enclosure voltage sensor.
Drives – Indicates the presence of enclosure-detected critical or warning
conditions in disk drives. Does not include "not installed" conditions.