HP 2000fc Reference Manual page 293

Modular smart array
Hide thumbs Also See for 2000fc:
Table of Contents

Advertisement

TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code
Event Type
225
Critical
226
Critical
227
Critical
228
Critical
229
Warning
230
Warning
231
Critical
232
Warning
Description
Background master write copy-on-
write operation has failed.
There was an internal I/O error.
Could not complete the write
operation to the disk.
A background master volume
rollback failed to start due to inability
to initialize the snap pool. All
rollback is in a suspended state.
Failure to execute rollback for a
particular portion of the master
volume.
Background rollback for a master
volume failed to end due to inability
to initialize the snap pool. All
rollback is in a suspended state.
The snap pool has reached the snap
pool warning threshold.
The snap pool has reached the snap
pool error threshold.
The system will take the action set up
in the policy. Default is to delete the
oldest snapshot.
The snap pool has reached the snap
pool critical threshold.
The system will take the action set up
in the policy. Default is to delete all
snapshots on the snap pool.
The maximum number of enclosures
allowed for the current configuration
has been exceeded.
Recommended Action
A probable hardware failure has
prevented the software from
operating successfully. Isolate and
replace and failed hardware
components. Once the hardware
issues have been corrected, it might
be necessary to delete all snapshots
and restart the controller.
Make sure the snap pool and the
vdisk on which this volume exists
are online. Restart the rollback
operation.
Restart the rollback operation.
Make sure the snap pool and the
vdisk on which this volume exists
are online. Restart the rollback
operation.
The user can set up the policy for
the snap pool.
You can expand the snap pool or
delete snapshots.
If the policy is to halt writes, then
you must free up space on the snap
pool master, or convert the master
volume to a standard volume in
order to resume operations.
The platform does not support the
number of enclosures that are
configured. The firmware has
removed the enclosure indicated by
this event from its configuration.
Appendix E Event Codes
293

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2000 series

Table of Contents