TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code
Event Type
45
Informational
47
Informational
48
Informational
49
Informational
52
Informational
53
Informational
or warning
55
Informational
56
Informational
58
Warning or
informational
59
Warning or
informational
Description
A communication failure has
occurred between the controller and
an EMP.
An error detected by the sensors has
been cleared.
The vdisk name has been changed.
A lengthy SCSI maintenance
command has completed.
Vdisk expansion has started.
This event is logged as informational
when a vdisk expansion has
completed or a RAID morph
operation is canceled by the user.
This event is logged as a warning if
the RAID morph operation fails.
A SMART event occurred on the
specified drive.
The Storage Controller has been
restarted.
A disk drive or other SCSI device
(such as an EMP) detected an error.
This event is logged as a warning for
serious errors such as parity or drive
hardware failure, and as
informational for other errors.
The controller detected an error while
communicating with the specified
SCSI device. The error was detected
by the controller, not the disk. This
event is logged as a warning for
parity errors, and as informational for
other errors.
Recommended Action
This operation can take days to
complete.
Impending drive failure. See "Disk
Drive Errors and Recommended
Actions" on page 300.
• For warning events that indicate
a disk drive is bad, replace that
drive module.
• For warning events that indicate
an expansion module is bad,
replace that expansion module.
• For warning events that indicate
a disk drive is bad, replace that
drive module.
• For warning events that indicate
an expansion module is bad,
replace that expansion module.
Appendix E Event Codes