Using Static Ip Settings; Setting The Telnet Timeout - HP 2000fc Reference Manual

Modular smart array
Hide thumbs Also See for 2000fc:
Table of Contents

Advertisement

Using Static IP Settings

To set IP values for Ethernet management ports:
1. Select Manage > General Config > LAN Configuration.
2. In the IP Address Assignment panel, set Source For IP Address to Manual.
3. In the IP Configuration panel for each controller, set appropriate values for your
network. Use dotted decimal notation.
The default IP address is 10.0.0.2 for controller A and 10.0.0.3 for controller B.
The default IP subnet mask is 255.255.255.0.
The default gateway IP address is 10.0.0.1.
You must set a unique IP address for each Ethernet port. Record the IP values you
assign.
4. Click Change LAN Configuration.
After 15 seconds you will be logged out and the browser will try to reconnect to
SMU using the new IP address.

Setting the Telnet Timeout

You can set the number of idle minutes before a Telnet connection to the storage
system is automatically terminated. To set the Telnet timeout:
1. Select Manage > General Config > LAN Configuration.
2. In the Telnet Configuration panel, set the Timeout value.
The allowed values are 0–255 minutes, where 0 means no timeout. The default is 60
minutes.
3. Click Change LAN Configuration.
Chapter 2 Configuring Your System for the First Time
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2000 series

Table of Contents