Xbcp 3 - Set Error Correction Level - Kyocera DP-1800 Command Reference Manual

Prescribe commands command reference manual rev 4.8
Hide thumbs Also See for DP-1800:
Table of Contents

Advertisement

PRESCRIBE Command Reference
XBCP 3 —
Format
Parameter
level:
Function
File
368
set error correction level
XBCP 3, level;
error correction level, integer from 0 to 8
The XBCP 3 command sets the error correction level by predetermined values. An
illegal value defaults to 0. Note that the execution of XBCP 3 overrides the setting of
XBCP 2 and remains valid until RES (reset) or XBCP 0.
To sets the error correction level to level 4:
!R! RES;
XBCP 3, 4;
XBAR;Error correction can also be set by level;ENDB;
EXIT;