PRESCRIBE Command Reference
SFNT —
Select current FoNT by typeface
Format
Parameters
type-face:
height:
font-number:
symbol-set:
compression:
shear:
Function
294
SFNT 'type-face'[, height [, font-number [, symbol-set, compression,
shear]]];
Name of the typeface of the font to be selected.
Height of the characters in points. The minimum value is 0.25 points and the maximum
value is 999.75 points, in 0.25-point increments.
Integer from 1000 to 65535
Symbol set, number from 0 to 65535; Refer to LaserJet Symbol Sets in Emulation of the
Technical Reference manual.
1 for normal character width. Smaller values for narrow characters; and larger values for
wider characters. The minimum value is 0.3 and the maximum value is 3.
0 for normal (unitalicized) characters. Positive values give forward italicization; and
negative values give backward italicization. The minimum value is -1 and the maximum
value is 1.
The SFNT command selects the font which matches the type-face parameters. It enables
the user to size its height, assign a font number and vary some of the font attributes so
that characters can appear compressed or sheared. All parameters except type-face are
ignored if a bitmap typeface is specified.
By designating a font number for a scalable font, it can later be retrieved by using a
FONT command. If you specify the symbol set, compression, and shear parameters
together, the FONT command recalls the font with these effects intact.
type-face should be a name from the font table in Section 4.2. of the Technical Reference
manual. Specify the full name exactly as it appears in the table, including case
sensitivity. This command is ignored and the current font is not changed if the typeface
name is not in the table or is not typed correctly.
height defines the size of the font, using the unit of points regardless of the current unit
setting. The SFNT command is ignored if the height value is out of the range. If the

Hide quick links: