Connection procedure
Follow these steps to connect the AC power cord:
Step1 Make sure that the PGND terminal is securely connected to the ground.
Step2 Move the power switch of the power module to the OFF position.
Step3 Move the bail latch holder to the left.
Step4 Connect one end of the supplied AC power cord to the AC power socket of the firewall, and the other
end to an AC power outlet.
Step5 Move the bail latch holder to the right to hold the power lord in position.
Step6 Move the power switch to the ON position.
Step7 Check the status of the power LED, PWR, on the front panel of the firewall. For the status of the power
LED, see Table 4-3.
Table 4-3 Description of power LED status
Status
OFF
Solid green
Solid red
Figure 4-11 Connect the AC power cord
(1) (2)
(3) (4)
(5)
(1) Bail latch holder
(3) Power socket
(5) Power switch
(7) Captive screw
Connecting the DC Power Cord
DC power supply
Rated voltage range: –48 VDC to –60 VDC.
DC power module
Figure 4-12 illustrates a DC power module.
No power is input.
The power module works normally.
The power module is faulty.
(6)
(7)
(2) AC power cord
(4) Power LED
(6) Power module holder