JVC KY-F70U - Sxga Imaging Camera Less Lens Instructions Manual page 54

Ky-f70 computer imaging camera instructions (827kb)
Hide thumbs Also See for KY-F70U - Sxga Imaging Camera Less Lens:
Table of Contents

Advertisement

6. Menu screen settings (continued)
PROCESS (1/3) screen (continued)
Menu item
GAMMA
@ @ @ @ @ @
LEVEL
MASTER BLACK
E54
Function/variable range
Used to set whether the gamma curve to determine the
reproduction of black is to be set using the standard value
or available for change.
NORMAL: the gamma curve is set using the standard
value (0.45)
ADJUST: set when changing the gamma curve
The gamma curve can be adjusted only when GAMMA is
set to ADJUST.
Increase the number: improves the reproduction of
Decrease the number: improves the reproduction of
[Variable range: 0.35 ~ 1.00 (21 steps)]
Used to adjust the pedestal level (master black), which is
the standard black during lens cap. To view black areas,
increase the pedestal level to brighten the entire screen.
Increase the pedestal level:
Decrease the pedestal level: decrease the number
[Variable range: –99 ~ 99]
black. However, the reproduction
quality of bright areas becomes
lower.
bright areas. However, the repro-
duction quality of black becomes
lower.
increase the number
Default value
NORMAL
0.45
0