Upgrading Firmware Via The Serial Port - SMC Networks 6724L2 - annexe 1 Management Manual

24-port fast ethernet switch
Hide thumbs Also See for 6724L2 - annexe 1:
Table of Contents

Advertisement

Notes: 1. If you use Windows HyperTerminal, disconnect
set the baud rate, and reconnect
2. The download file should be an SMC6724L2 binary file
from SMC; otherwise the agent will not accept it.
4. After the file has been downloaded, the console screen will
display information similar to that shown below. Press Enter to
download to permanent memory, change the baud rate back
to 19200, press Enter to start decompressing the new firmware,
then press Enter to open the Log-on screen.
XModem Download to 0x00400020: ... SUCCESS !
(P)ermanent or (T)emporary Download: [P]
Update RunTime Image at 0x03040000 ...
Change to original Baud Rate
and Press <ENTER> to Run Application !!!
Decompress now............ !!!
run-time code starting now. !!! Starting System...
MAINBOARD OCTOPUS0 RAMBIST TEST......... PASS!
MAINBOARD OCTOPUS1 RAMBIST TEST......... PASS!
MAINBOARD OCTOPUS2 RAMBIST TEST......... PASS!
MAINBOARD OCTOPUS3 RAMBIST TEST......... PASS!
MAINBOARD DOLPHIN
MAINBOARD STARFISH RAMBIST TEST......... PASS!
Press <Enter> to start UI
For details on managing the switch, refer to Chapter 2 for
information on the out-of-band console interface, or Chapter 3 for
information on the Web interface.