6.3.9.2. Humidifier
With this option, the installer has the option of selecting whether a
humidifier is installed, to humidify with the fan in low speed, and the
time interval for changing the humidifier pad. After the selections are
made, touch SAVE.
• Humidifier Installed: Yes or No. Humidifier selection made during
installation; otherwise default = No
• Change Pad: Selectable from 1 to 24 months. Default = 12 months
• Humidify with Fan: Yes or No. Default = No
6.3.9.3. Ultraviolet Lights
With this option, the installer has the option of selecting whether
ultraviolet lights are installed, and the time interval for changing the
ultraviolet lights. After the selections are made, touch SAVE.
• UV Lights Installed: Yes or No. UV Lights selection made during
installation; otherwise default = No
• Change Interval: Selectable from 1 to 48 months. Default = 12
months
6.3.9.4. Ventilator
When a ventilator is installed, the installer has the option of selecting the
time interval for cleaning the ventilator. After the selections are made,
touch SAVE.
• Clean Interval: Selectable from 60, 90, 120, 150 or 180 days. Default
= 90 days
NOTE: This option may NOT be available with the ERVXXNVA
ventilator due to its simplified control design.
6.3.10. Utility Curtailment
NOTE: Utility Curtailment and Utility Saver functions are different than
the Utility Demand Response function described in the Owner's Manual.
Utility Curtailment/Utility Saver uses the UTIL and Y2 (or equivalent)
54