• The installer will first be instructed to select the appropriate size of the
outdoor unit; then, touch SELECT.
A13118
5.3. Indoor Evaporator Selection
If a furnace is installed with a variable capacity heat pump or an
Evolution Vheat pump or air conditioner, a screen will appear to select
the installed indoor evaporator coil. This selection is used to adequately
calculate the refrigerant charge required while in the heat pump charging
screens under Refrigerant Charging Evolution VSystems Section. Select
"other" for non-Bryant evaporators.
5.4. Electric Heater Selection
If the indoor equipment is a fan coil, the control will display "Searching
for heater" until one is found. If the electric heater is not self-identifying,
the select heater screen will appear. Touch the appropriate heater size;
then, touch SELECT.