6.3.2.6. Fan Coil G Terminal Alert Label
Once the G Terminal Alert label has been entered, it is shown both on the
main screen and in the notification email when the alert becomes active.
A14224
6.3.3. Furnace
First touch SETUP, then touch FURNACE to set up the parameters for
the furnace unit.
A14225A_2
6.3.3.1. Furnace Airflow
Selects the airflow of the furnace when heating. EFFICIENCY is the
airflow used to meet specified ratings, COMFORT is a decreased
airflow used to increase the output air temperature and provide increased
comfort.
For the Low heat rise option, set to ON if the system contains a bypass
humidifier. The ON setting will increase the furnace low heat airflow.
After the selections are made, touch SAVE.