To take Powerlog into use, go to the control panel's
Once selected, choose whether 2 or 3 power levels are used. Still in the Welding parameters view, set up the power
levels for this function. The parameters available for adjustment are:
Wire feed speed and its minimum and maximum values
Voltage / Fine tuning
Dynamics (not available with MAX Cool).
The wire feed speed of each level can also be adjusted in the Home view. Pressing the left control knob button changes
between levels. Green color indicates the selected Powerlog level:
Powerlog trigger logic is not available together with WiseSteel feature or with manual MIG, MAX Speed, MAX Pos-
ition or DPulse processes.
Powerlog trigger logic cannot be used together with a remote control. If a Powerlog memory channel is selected
when a remote control is in use, the trigger logic is automatically switched to 4T.

3.4.2 1-MIG

X5 WF AP/APC
1-MIG or "Auto" is a MIG/MAG welding process where the welding voltage is defined automatically when you adjust the
wire feed speed. The voltage is calculated based on the welding program in use. The process is suitable for all materials,
shielding gases and welding positions. 1-MIG supports WiseSteel, WisePenetration and WiseFusion features, as well as
various optimized welding programs.
>> To take 1-MIG into use, go to the
If there aren't any 1-MIG memory channels available, create a new one for 1-MIG process by selecting an available 1-MIG
welding program for the channel. Follow the instructions in "AP/APC control panel: Applying welding programs" on
page 117 (AP/APC).
When the X5 equipment is in MIG mode, the '0' memory channel is always reserved for the manual MIG process. All
other memory channels are available for any process.

3.4.3 WiseFusion feature

© Kemppi
Welding parameters view
Memory channels view
and select an existing memory channel with 1-MIG process.
121
and select Powerlog as the trigger logic.
X5 FastMig