Download Print this page

X5 Cooling Units - Kemppi X5 FastMig Operating Manual

Hide thumbs Also See for X5 FastMig:

Advertisement

5.3 X5 cooling units

X5 Cooler
X5 Cooler
Feature
Supply voltage
Maximum supply current [ I
Cooling power at 1 l/min
Maximum coolant pressure
Recommended coolant
Operating temperature range
Storage temperature range
EMC class
Degree of protection
Tank volume
External dimensions
Weight without accessories
Standards
X5 Cooler MV
X5 Cooler MV
Feature
Supply voltage
Supply voltage
Maximum supply current [ I
Maximum supply current [ I
Cooling power at 1 l/min
Maximum coolant pressure
Recommended coolant
Operating temperature range
Storage temperature range
EMC class
Degree of protection
Tank volume
External dimensions
Weight without accessories
Standards
© Kemppi
]
1max
]
1max
]
1max
Value
380...460 V ±10 %
0.7 A
1.1 kW
4 Bar
Kemppi MGP 4456
-10...40 °C
-40...60 °C
A
IP23S
3 l
L x W x H
730 x 263 x 288 mm
14.3 kg
IEC 60974-2, -10
Value
380...460 V ±10 %
MV low range
220...230 V ±10 %
0.7 A
@MV low range
1 A
1 kW
4 Bar
Kemppi MGP 4456
-10...40 °C
-40...60 °C
A
IP23S
3 l
L x W x H
730 x 263 x 288 mm
15.7 kg
IEC 60974-2, -10
168
X5 FastMig
Operating manual - EN
1920960 / 2440

Advertisement

loading
Need help?

Need help?

Do you have a question about the X5 FastMig and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

X5 fastmig autoX5 fastmig pulse