12
Following are the minimum reading distances for CK61s using the 2D and
near-far range area imagers. When correctly mounted, an exit window
reduces reading distances by about 4%.
2D Area Imager Reading Distances with 0.04" Setbacks
Symbology
Density
MaxiCode
35 mil
Data Matrix
15 mil
PDF417
10 mil
8 mil
6.6 mil
Code 39
15 mil
10 mil
8 mil
UPC
13 mil
Near-Far Range Area Imager with 0.350 in (0.889 cm) Setback
Symbology Density
Code 39
0.10 mm (3.8 mil)
0.25 mm (10 mil)
0.5 mm (20 mil)
1 mm (40 mil)
1.3 mm (51 mil)
2.54 mm (100 mil)
EAN 100%
0.33 mm (13 mil)
Use Intermec Settings to configure these imager commands. For help using
"Using the Intermec Settings Applet" on page
Intermec Settings, see
For information on the commands and their parameters, see the Intermec
Computer Command Reference Manual (P/N 073529), available from the
Intermec web site at www.intermec.com.
The CK61 should connect the following scanner models:
• 1551
• 1553
• 1555
• ScanPlus 1800SR
• 1800ST
• 1800VT
• Scan Image 1470
• SF51
CK61 Mobile Computer with Windows Mobile User's Manual
Near Distance
4.98 cm/ 1.96"
9.30 cm/ 3.66"
7.77 cm/ 3.06"
8.28 cm/ 3.26"
11.33 cm/ 4.46"
5.23 cm/ 2.06"
8.03 cm/ 3.26"
11.33 cm/ 4.46"
6.25 cm/ 2.46"
Near Distance
Far Distance
18.889 cm (7.437 in)
31.111 cm (12.248 in)
18.889 cm (7.437 in)
68.111 cm (26.815 in)
19.889 cm (7.830 in)
109.111 cm (42.957 in)
40.889 cm (16.098 in)
219.111 cm (86.264 in)
100.889 cm (39.720 in)
309.111 cm (121.697 in)
130.889 cm (51.531 in)
429.111 cm (168.941 in)
22.889 cm (9.011 in)
99.111 cm (39.020 in)
Far Distance
33.92 cm/ 12.96"
16.41 cm/ 6.46"
22.76 cm/ 8.96"
20.22 cm/ 7.96"
15.77 cm/ 6.21"
29.87 cm/ 11.76"
23.27 cm/ 9.16"
19.20 cm/ 7.56"
31.65 cm/ 12.46"
17.